Accident Summary Nr: 202543989 - Laborer Suffers Multiple Fractures When Trench Collapses

Accident Summary Nr: 202543989 -- Report ID: 0950641 -- Event Date: 06/04/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31486250906/04/20121611237310Prkacin Company

Abstract: At approximately 3:00 p.m. on June 4, 2012, an employee was working in a trench, preparing the trench for a pipe bed. He was performing a regularly assigned task of removing soil and debris with a shovel. The trench collapsed. The employee was trapped. He suffered multiple rib fractures and a fractured arm. The employee was rescued and transported to UCLA Medical Center, where he was hospitalized. The Cal/OSHA Division was notified of the accident by the Los Angeles Fire Department at 3:50 p.m. on June 4, 2012. The Division initiated an inspection at 5:25 p.m. on June 4, 2012. The employee was employed by Prkacin Company, Glendale, California, a pipeline construction company. The investigation determined that the employee had been working at the job site for two months, performing the duties of a laborer. At the time of the accident, he was assigned to remove soil and broken pipe from the bottom of a trench measuring 21 feet deep by 25 feet long. Trench shields extended from top to bottom along most of the length of the trench, but the 4-foot section at the end of the trench was shielded only along the bottom 4 feet. The soil had sloughed away from the trench sides in the area of the 4-foot shield, creating a void where the employee would discard the shoveled soil and debris. The soil in the trench was a very granular type C. While the employee was in the trench, soil sloughed off the trench wall behind the full-length trench shields and flowed into the trench. The flowing soil pushed the employee into the trench jacks, resulting in his injuries. The employee was working within close proximity to a witness at the time of the accident.

Keywords: FRACTURE, SLOUGH, CONSTRUCTION, TRENCH, CAUGHT BETWEEN, RIB, ARM, TRENCH JACKS, CAVE-IN, SHOVEL
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Sewer/water treatment plant Maintenance or repair $250,000 to $500,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 314862509 Hospitalized injury Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Site grading and rock removal
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.