Accident Summary Nr: 202532214 - Employees Suffers Chemical Exposure

Accident Summary Nr: 202532214 -- Report ID: 0950635 -- Event Date: 09/03/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
31364908909/10/20132022311513Saputo Cheese Usa,Inc

Abstract: At approximately 4:45 a.m. on September 3, 2013, a coworker was approaching the Manning Ammonia display panel located in plant's chemical room adjacent to the plant's old engine refrigeration room, heard an audible ammonia system alarm coming from the panel. The coworker approached the Manning Ammonia display panel and saw that the Manning display panel was reading 250 parts per million. After observing the display panel the coworker went to the old engine refrigeration room's north door, opened it, and observed a dense vapor cloud hovering above the floor. The coworker closed the old engine refrigeration room's door and notified the Supervisor. The Supervisor evacuated the plant and called Emergency Medical Service. As the Supervisor evacuated the plant, the coworker returned to the old engine refrigeration room with a full face respirator, ammonia gloves and a sulfur stick, and observed the oil drain plug from the High Temperature Accumulator lying on the floor in a puddle of oil. The coworker picked up the oil drain plug and screwed the drain plug back into the elbow of the accumulator's drain and left the room. Employees #1, 2, and 3 worked as packers were working lines 5, 1 and 2. As they were being evacuated the employees started suffering health problems such as irritation in their throats, numbness around the mouth region and difficulty breathing. EMS County Paramedics treated the employees and transported them to St. Francis Hospital, where they were observed for exposure to chemicals and anxiety. The employees were released after two hours observation.

Keywords: THROAT, VAPOR, AMMONIA, MOUTH, ALARM, INHALATION, CHEMICAL VAPOR, EVACUATION, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 313649089 Non Hospitalized injury Asphyxia Hand packers and packagers
2 313649089 Non Hospitalized injury Asphyxia Hand packers and packagers
3 313649089 Non Hospitalized injury Asphyxia Hand packers and packagers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.