Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202505285 - Employee Is Killed When Crushed by Compactor

Accident Summary Nr: 202505285 -- Report ID: 0352450 -- Event Date: 11/12/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31278081011/12/20084212562111Potomac Disposal, Inc.

Abstract: On November 12, 2008, Employee #1 and a coworker were using a side-load garbage truck to collect recyclable materials. Employee #1 was working the paper collection side and the coworker was working the glass and plastic side. The truck was equipped with compactors on both sides and each side could be operated either independently or together, depending upon the settings. There was an operational audible alarm to warn the worker on the opposite side when a compactor was in motion. As Employee #1 reached into the compactor on the paper side to clean it out, either he or the coworker engaged the compactor. Employee #1 was pinned in the compactor and was killed.

Keywords: GARBAGE TRUCK, PINNED, ALARM, CRUSHED, TRUCK, TRASH COMPACTOR, COMMUNICATION, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 312780810 Fatality Asphyxia Garbage collectors

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close