Accident Summary Nr: 202502522 - Employee Is Struck and Killed by Crossarm

Accident Summary Nr: 202502522 -- Report ID: 0352440 -- Event Date: 07/11/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31363726607/11/20099999811310C W Wright Construction Company

Abstract: While raising a 230-kV transmission line from the ground, using an 8-in. pulley, the cross arm of the transmission tower buckled, and pinned Employee #1 against the main body of the tower, crushing him. Employee #1 was pronounced dead on the scene.

Keywords: ASPHYXIATED, PINNED, ELECTRICAL WORK, CROSSARM, STRUCK BY, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 313637266 Fatality Asphyxia Electrical and electronic technicians
2 313637266 Fatality Asphyxia Electrical and electronic technicians

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.