Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202493755 - Foreman Is Injured in Fall While Dismantling Scaffold

Accident Summary Nr: 202493755 -- Report ID: 0950621 -- Event Date: 07/13/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31651806708/30/20121611237310Aj Vasconi Inc

Abstract: On July 13, 2012, Employee #1, a labor foreman for AJ Vasconi, Inc., was working at a bridge construction project in Smartsville, CA. He was disassembling the form scaffold on a pier wall by removing nails from the planking and scaffold jack system. After lowering one of the 2 foot by 12 foot planks, Employee #1 stepped back onto the other plank that was cantilevered over the bracket. This second plank, which had been previously secured by nails, teetered over, causing Employee #1 to lose his footing. Employee #1 fell approximately 13 feet to the ground below. He required hospitalization for a ruptured intestine and an elbow laceration. Employee #1 was trained and experienced in the erection and dismantling of the scaffold system in use. However, the scaffold had been erected by a coworker, who was trained as a "bridge carpenter" by the union hall. According to the employer, a general engineering contractor, such training should have included the use of similar types of formwork/false work scaffolding. The employer stated the company had not trained the coworker on the company's erection procedures prior to the accident.

Keywords: ABDOMEN, DISMANTLING, CONSTRUCTION, RUPTURE, FALL, FALL PROTECTION, ELBOW, LOST BALANCE, UNTRAINED, SCAFFOLD
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Bridge New project or new addition $500,000 to $1,000,000 13

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 316518067 Hospitalized injury Other Supervisors; handlers,equip-cleaners,laborers nec Distance of Fall: feet
Worker Height Above Ground/Floor: 13 feet
Cause: Forming for piers or pylons
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.