Accident Summary Nr: 202491551 - Employee Fractures Back in Training Exercise

Accident Summary Nr: 202491551 -- Report ID: 0950621 -- Event Date: 03/06/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31456775103/28/20118221611310University Of California, Davis

Abstract: On March 6, 2011, Employee #1 and two coworkers, all firefighters, were practicing an experimental emergency bailout procedure. Based upon a photographic slide viewed in a previous training session, the three man crew used a chair placed against a wall as an anchor along with another backup secure anchor in an emergency bailout exercise. One of the coworkers acted as the "edge attendant" while Employee #1 bailed out of the window and began to repel 16 feet to the sidewalk below. As he repelled down 6 feet, the chair that his rope was anchored to flipped out of the window. The backup, secure anchor did not engage immediately because of too much rope slack behind the anchor chair and too much slack in front of the secure anchor. Employee #1 fell 10 feet to the sidewalk, landing on his back. He sustained a fracture to his back and was hospitalized for treatment.

Keywords: ANCHOR, FIREFIGHTER, FRACTURE, CHAIR, BACK, FALL, FALL PROTECTION, TRAIN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 314567751 Hospitalized injury Fracture Firefighting occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close