Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202490850 - Employee Is Injured When Concrete Rail Crushes Foot

Accident Summary Nr: 202490850 -- Report ID: 0950621 -- Event Date: 11/06/2010
Inspection NrDate OpenedSICNAICSEstablishment Name
31453457912/07/20101611237310Teichert Construction

Abstract: On November 6, 2010, Employee #1 was working as an apprentice operating engineer on a construction site. Employee #1 was working with Coworker #1, and excavating operator, and they were relocating approximately ten 8000-pound sticks of concrete K-Rail, each measuring 20 feet long. The sticks were normally joined into a line at each end by "pins" that were secured by loops imbedded into the ends of the concrete K-Rails. The loops at one end of the stick were located above the loops on the adjoining stick and under the loops of the adjoining stick on the opposite end. The pins had been removed to allow the removal of a single K-Rail from the line of K-Rails. Employee #1 stood approximately 5 feet from the K-Rails in a position where he and Coworker #1 could see one another. Coworker #1 lifted one stick with the excavator, and in turn that stick lifted a second stick due to the overlapping loops. Suddenly, the second K-Rail that was raised slipped off the loops of the secured K-Rail, and pivoted and landed on Employee #1's right foot. Employee #1 suffered severe injuries to his foot and was hospitalized for treatment of his injuries.

Keywords: CONCRETE BEAM, CRUSHED, EXCAVATOR, FOOT
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street Other Under $50,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 314534579 Hospitalized injury Amputation Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Site clearing and grubbing
Fatality Cause: Unloading-loading equipment/material (except by cr

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close