Accident Summary Nr: 202490413 - Employee Injures Legs While Cleaning Gutters

Accident Summary Nr: 202490413 -- Report ID: 0950621 -- Event Date: 03/29/2010
Inspection NrDate OpenedSICNAICSEstablishment Name
31442891304/06/20101761238390Commercial Gutter Incorporated

Abstract: On March 29, 2010 at approximately 2:00 p.m., #1 was seriously injured at the ER's jobsite located at 315 North Cottonwood Rd in Woodland CA. ER is a full service commercial and residential gutter fabrication, installation and maintenance provider. #1 was working on the maintenance department cleaning gutters on a two-story residence at the time of the accident. According to all accounts #1 was standing on an A-frame ladder (not folded open) placed on a partial first-story roof/awning over the front of the house, cleaning the second story gutter when the ladder became unstable. #1 attempted to jump free, landing on the first-story roof and rolling off to the concrete below, seriously injuring both legs. According to #1 and the ER they had an extension ladder that secures to the gutter/eve that he could have used (according to ER, should have used). #1 stated that he was the foreman on the job and made the decision to use the smaller ladder because it seemed easier.

Keywords: RAIN SPOUT, EXTENSION LADDER, CLEANING, LADDER, LADDER HOOKS, FALL PROTECTION, CONCRETE, LEG, UNSTABLE POSITION
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling Maintenance or repair Under $50,000 2

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 314428913 Hospitalized injury Fracture Supervisors, cleaning and building service workers Distance of Fall: feet
Worker Height Above Ground/Floor: 9 feet
Cause: Temporary work (buildings, facilities)
Fatality Cause: Fall from roof

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.