Accident Summary Nr: 202484200 - Employee's Finger Is Amputated by Wood Splitter

Accident Summary Nr: 202484200 -- Report ID: 0950621 -- Event Date: 08/19/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
12020251010/05/20060851115310Cool Forest

Abstract: On August 19, 2006, Employee #1 was operating a gas-powered wood splitter. While operating the lever to push the hydraulic arm forward with his right hand and holding the wood with his left gloved hand, his left middle finger became caught between the iron wedge of the splitter and the wood to be split. Employee #1 was treated at Marshall Medical Center for an amputation of the finger.

Keywords: AMPUTATED, FINGER, GLOVE, CAUGHT BETWEEN, HYDRAULIC TOOL, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 120202510 Non Hospitalized injury Amputation Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.