Accident Summary Nr: 202478376 - Employee Is Burned While Connecting a Power Plug

Accident Summary Nr: 202478376 -- Report ID: 0950644 -- Event Date: 04/17/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31634413406/14/20122099311830Mission Foods

Abstract: At 2:15 a.m. on April 17, 2012, Employee #1 of Mission Foods suffered second and third degree burns to his left forearm and hand and right hand with no skin grafting, when sparks erupted during the connection of a power plug into a 480-volt power outlet on the wall of a wash room. Mission Foods has been in the business of making tortillas over many years at Rancho Cucamonga, California, and employed about 800 employees on its payroll on inspection day. The employer also has another tortilla manufacturing facility in El Monte, California. Employee #1 was employed about nine months as a sanitation technician with the above employer before the accident occurred to him at the Rancho Cucamonga facility. At time of the accident, Employee #1 was plugging the 480-volt washer machine electrical plug to a power outlet on the wall when sparks erupted and struck Employee #1's hands and forearm, resulting in burn injuries. Employee #1 was wearing latex gloves not approved for this job when the accident occurred, per the safety official who participated in the walk around inspection on June 20, 2012. The safety official also stated that Employee #1 was forcing the 4-pin power plug of the NILFISK ALTO POSEIDON 7 washer machine into the 480-volts AC outlet on the wall instead of twisting the plug slightly and then pressing it into the outlet. Employee #1 was interviewed at a later date about the accident and stated that he was not trained for the task he was doing at time of the accident. Employee #1 was transported to Arrowhead Medical Center in Colton by paramedics for medical treatment where he was treated for a couple of hours and released.

Keywords: BURN, GLOVE, FOREARM, SPARK, ELECTRICAL BOX, UNTRAINED, WASHING MACHINE, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 316344134 Hospitalized injury Burn/Scald(Heat) Technicians, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close