Accident Summary Nr: 202476594 - Employee Suffers Amputation on Rotary Die Cutter

Accident Summary Nr: 202476594 -- Report ID: 0950636 -- Event Date: 11/03/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31266312303/08/20102657322212Smurfit-Stone Container Enterprises Inc

Abstract: At approximately 2:10 p.m. on November 3, 2009, Employee #1 was working on a machine that automatically die cuts corrugated paper boxes, known as a rotary die cutter. Employee #1 suffered an amputated right thumb and was treated at St. Jude Heritage Occupational Medical Center in La Mirada, CA, then transferred to Western Hand and Orthopedic in Downey, CA. During the accident, the drive shaft powering belts, or beater belt, would not run/rotate. Employee #1 was taught by a coworker two months prior to the accident to start the rotations of the belt's drive shaft by manually turning it. While manually turning the drive shaft Employee #1's gloved hand was caught in the key way on the shaft causing his amputation injury. The Ward Turner 783 Rotary Die Cutter was missing hazardous nip point guarding at various places on the machine. The Division was notified by the SSCEI's regional human resources manager on February 12, 2009.

Keywords: AMPUTATED, DIE CUTTING PRESS, GLOVE, THUMB, NIP POINT, DRIVE SHAFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury
1 312663123 Non Hospitalized injury Amputation

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close