Accident Summary Nr: 202475703 - Employee Is Killed When Struck by Cable or Anchor

Accident Summary Nr: 202475703 -- Report ID: 0950636 -- Event Date: 06/25/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31266125906/25/20094212562111Waste & Recycling Services, Inc.

Abstract: At approximately 5:00 p.m. on June 25, 2009, Employee #1, a mechanic at Waste & Recycling Services, Inc., Irwindale, CA, replaced a broken 85 ft by 0.875 in. steel wire rope hoist cable on a 1996 Volvo/GM truck equipped with a Amrac hydraulically powered cable hoist. The wire rope was supplied by the manufacturer with one end formed into a loop with a thimble and a swage which retained a closed steel link and weighed approximately five pounds. The other end of the wire rope was retained with three Crosby clamps, which had been installed by the employee with air tools. The company would perform waste collection and recycling services and had nine employees and operates six waste collection trucks, including two trucks equipped with hydraulically powered cable hoists. The employee was working alone after 4:00 p.m. and was later discovered lying in a pool of blood adjacent to the hydraulic cable hoist controls. He was pronounced dead at the scene by Los Angeles County fire paramedics. The physical evidence indicated that the employee had placed the closed steel link (connected to the swaged end of the wire rope) on a retaining hook welded to the truck frame. The employee operated the hydraulic controls to tension the wire rope at which point the welds securing the steel hook to the truck frame failed. The steel hook was discovered approximately 75 ft away from its original position. Inspection of the steel hook also revealed that 50 percent of the welded surface of the hook had been rusted through and was not attached to the truck frame prior to the accident. When the steel hook broke free from the truck frame, the employee was struck by the steel link attached to the swaged end of the wire rope and sustained a fatal head injury. The employer received Title 8 CCR Section 3203(a), Section 3328(a), Section 3328(g) and 4345(a) citations, but no accident-related citations were issued.

Keywords: HEAD, WIRE ROPE, INADEQUATE MAINT, HOIST, TRUCK, STRUCK BY, MECH MALFUNCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 312661259 Fatality Other Heavy equipment mechanics

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close