Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202472270 - Employee killed when crushed by ROPS of overturned loader

Accident Summary Nr: 202472270 -- Report ID: 0420600 -- Event Date: 11/12/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31155150111/13/20071629238910Valleycrest Landscape Development, Inc.

Abstract: On November 12, 2007, Employee #1 and a coworker were moving two palm trees from a holding area to a planting area at the edge of a small lake in a new residential golf club community. The coworker was using a TCM loader to transport thew two palsm, Employee #1 was walking alongside it. The loader was driving on a slight slope of approximately 13 degrees, beside a paved cart path. When the loader neared the planting area, the coworker turned it to the left, coming down off the slight slope to cross the paved cart path. As the loader turned to the left, the palm trees also swung to the left, causing the loader to overturn onto Employee #1. He became caught under the ROPS support and died of crushing injuries to his his chest and abdomen.

Keywords: CHEST, ABDOMEN, UNSECURED, LOAD SHIFT, ROPS, CAUGHT BY, CONSTRUCTION, CRUSHED, LOADER, OVERTURN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other heavy construction New project or new addition $500,000 to $1,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 311551501 Fatality Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Landscaping
Fatality Cause: Crushed/run-over of non-operator by operating cons

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close