Accident Summary Nr: 202467460 - Four Employees Are Injured When Scaffold Collapses

Accident Summary Nr: 202467460 -- Report ID: 0950643 -- Event Date: 11/21/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31243008511/21/20081742238310Ross Plastering, Inc.

Abstract: At approximately 12:15 p.m., on November 21, 2008, four employees were working on a scaffold that was being erected in the courtyard of a multi-unit apartment complex under construction. Two of the employees were erecting the scaffolding. The other two employees were part of a crew that was delivering drywall. The scaffold was being erected in two side by side sections that were bridged. The western section of the scaffolding was completed under the direction of a Qualified Scaffold Erector. The eastern section of the scaffold was being erected after the completion of the western section. The eastern section was erected by another crew. The eastern section of scaffolding was built up to the fifth level, approximately 32 ft 3 in. high. A Gradall Model No. 544-D entered the courtyard through the north entrance with a bundle of green board drywall. Based on conflicting witness statements, and no direct evidence, if it is not clear whether or not the Gradall struck the scaffolding. Employees #1, 2, 3, and 4 were injured when the scaffold collapsed. Three of the employees fell to the ground. One employee was able to jump from the scaffold into a window opening. An investigation revealed that not all of the required ties between the scaffold and the buildings were installed. Employee #1 was hospitalized for unspecified fractures. Employee #2 was hospitalized for a concussion. Employees #3 and 4 were hospitalized for unspecified contusions and abrasions.

Keywords: ERECTION PROCESS, FRACTURE, COLLAPSE, UNSECURED, CONSTRUCTION, FALL, STRUCK BY, CONCUSSION, CONTUSION, SCAFFOLD
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling New project or new addition $5,000,000 to $20,000,000 4

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 312430085 Hospitalized injury Fracture Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: 20 feet
Cause: Emplacing reinforcing steel
Fatality Cause: Fall from/with scaffold
2 312430085 Hospitalized injury Bruise/Contus/Abras Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: 20 feet
Cause: Emplacing reinforcing steel
Fatality Cause: Fall from/with scaffold
3 312430085 Hospitalized injury Bruise/Contus/Abras Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: 20 feet
Cause: Emplacing reinforcing steel
Fatality Cause: Fall from/with scaffold
4 312430085 Hospitalized injury Concussion Construction trades, n.e.c. Distance of Fall: feet
Worker Height Above Ground/Floor: 20 feet
Cause: Emplacing reinforcing steel
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.