Accident Summary Nr: 202467262 - Worker Breaks Leg in Thirteen Foot Fall from Scaffolding

Accident Summary Nr: 202467262 -- Report ID: 0950643 -- Event Date: 02/17/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31243095202/26/20091741238140Cornerstone Masonry, Inc.

Abstract: At approximately 1:00 p.m. on February 17, 2009, Employee #1, a Supervisor and two coworkers were using scaffolding and setting blocks on a new construction building at a sewer treatment plant. The equipment being used was Non-Stop Scaffolding. The scaffolding was a crank up type of scaffolding. The scaffold planks were placed on the support brackets with a nine-inch over hang. Employee #1 walked past the support bracket onto scaffold plank that caused the plank to fall. The scaffold plank fell when it walked in a northerly direction and employee #1 was walking in a southerly direction and the plank slipped past the support bracket which caused Employee #1 to fall to the ground. Employee #1 fell about thirteen-feet from a crank up scaffold assembly. Employee #1 was transported to Kern Medical Center, Bakersfield; CA. Employee #1 broke the femur of his left leg after falling thirteen-feet. The planks had been inspected prior to use on the date of the incident, two of the workers were categorized as competent persons trained and experienced on the type of scaffolding that was being used by the employer.

Keywords: PLANKING, FRACTURE, PLANK, SCAFFOLD COLLAPSE, FALL, LEG, SCAFFOLD, SCAFFOLDING
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Sewer/water treatment plant New project or new addition $5,000,000 to $20,000,000 1 14

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 312430952 Hospitalized injury Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 13 feet
Cause: Exterior masonry
Fatality Cause: Fall from/with scaffold

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.