Accident Report Detail
Accident Summary Nr: 202466041 - Employee's Finger Is Amputated by Chain and Sprocket
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 310200332 | 03/04/2008 | 3411 | 332431 | Rexam Beverage Can Americas |
Abstract: At approximately 4:18 p.m. on February 28, 2008, Employee #1 was working for beverage can manufacturer. When he reached into the 12 oz Body Maker N:16 to remove a can from the can pocket, his right index finger was amputated by an unguarded rotary cup infeed drive chain and sprocket. Employee #1 was hospitalized. The investigation concluded that violation of CCR Title 8 Section 4075(a) was the cause of this accident. As a result, the Division issued serious accident related citation to the employer according CCR Title 8 Section 4075(a).
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 310200332 | Hospitalized injury | Amputation | Machine operators, not specified |
Translate