Accident Summary Nr: 202452140 - Burn - Electric Drill Ignites Flammable Vapors

Accident Summary Nr: 202452140 -- Report ID: 0950642 -- Event Date: 10/23/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30716686810/24/20051795238910L&M Loader Service

Abstract: Workers were removing a 75.7-kiloliter gasoline tank and a smaller 45.4-kiloliter fuel storage tank. Before excavation began, the workers drained the storage tanks, but a few centimeters of fuel still remained at the bottom of the storage tank. Two days earlier, one of the employees was excavating around the storage tank when he struck the storage tank with the excavator bucket and punctured a hole in the tank. The hole allowed pea gravel surrounding the tank to enter. On the day of the accident, the same employee entered the unprotected excavation and was working at a depth of approximately 3.4 meters. He used a shovel to remove the pea gravel from the storage tank through the hole. He then began patching the hole with a scrap of fiberglass, attaching it to the outside of the tank using a Black and Decker 18-volt, battery-powered, cordless drill to drive 51-millimeter-long self tapping screws. He had not tested the tank for the presence of flammable vapors. While he was driving the second screw, the storage tank exploded, engulfing the employee in flames. He was burned over 60 percent of his body and receiving second- and third-degree burns to his arms, back, chest, legs, and face. He was hospitalized for his injuries for approximately 3 weeks.

Keywords: BURN, E GI V, EXCAVATION, ELECTRICAL, FLAMMABLE VAPORS, STORAGE TANK, EXPLOSION, ELECTRIC DRILL, EQUIPMENT APPROVAL
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Excavation, landfill Demolition Under $50,000 1

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 307166868 Hospitalized injury Burn(Chemical) Laborers, except construction Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Fire/explosion

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.