Accident Summary Nr: 202447447 - Employee's leg injured when K-rail flips over

Accident Summary Nr: 202447447 -- Report ID: 0950633 -- Event Date: 10/30/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31060131512/10/20071611237310Atkinson Contractors Lp

Abstract: At approximately 8:35 p.m. on October 30, 2007, Employee #1, a laborer, was working with a forklift operator to transport 8,000 lb K-rails westbound on Route 10 in Redlands, CA. The coworker was operating a Sky Trak variable reach, rough terrain forklift truck, model 10042, serial #13322, with a 10,000 lb maximum load capacity, while Employee #1 was assisting on the ground. The 20 ft long by 32 in. high K-rails were 24 in. wide at the bottom, narrowing to 6 in. wide at the top. Each rail had two 2 in. high by 23.5 in. wide scupper or fork pockets that were 8 ft apart. The K-rail also had two 4 in. diameter lifting holes located 12 in. from the top and 3 ft 9 in. from each end.They were using approximately 41 lb C-shaped K-rail hooks manufactured by Don De Cristo Concrete Accessories, Code KRHOOK, to pick up and move the K-rails. The approximately 22 in. by 16 in. by 3/4 in. thick hooks easily slid under the K-rail's 2 in. high scupper holes. At the time of the accident, the load had reached its destination and was placed on the ground. Employee #1 removed the hooks from the K-rail lifting holes and they dropped to the ground between the forklift and the K-rail. The coworker was not aware that the left hook had become wedged under the left scupper, and he boomed up and moved the forklift back. This caused the K-rail to flip over in the direction where Employee #1 was standing. The left corner of the K-rail crushed his left leg below the knee. He was transported to Loma Linda University Medical Center, where he was hospitalized for two weeks.

Keywords: ATTACHMENT HOOK, METAL RAIL, CAUGHT BY, CONSTRUCTION, INDUSTRIAL TRUCK, MECH MAT HANDLING, STRUCK BY, LEG
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street New project or new addition $5,000,000 to $20,000,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310601315 Hospitalized injury Amputation Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Traffic protection
Fatality Cause: Unloading-loading equipment/material (except by cr

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.