Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202446258 - Employee injured when excavation caves in

Accident Summary Nr: 202446258 -- Report ID: 0950633 -- Event Date: 06/23/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31059922006/23/20071521236115Michael Mullins

Abstract: At 1:04 p.m. on June 23, 2007, Employee #1 and a coworker were installing a septic pit in the front yard of a two-story duplex under construction. The coworker was using a John Deere loader-backhoe to dig the excavation, which varied in depth from 15 ft to 20 ft. Employee #1 was working inside the excavation when the walls caved in on him. It took over 80 rescuers about 8 hours to free him. Employee #1 sustained multiple injuries and was hospitalized for over one week. When the Fire Department arrived on the scene, the loader-backhoe was still extended into the hole. None of the excavation walls has been shored or otherwise protected from collapsing inward.

Keywords: EXCAVATION, INSTALLING, LOADER/BACKHOE, WORK RULES, CONSTRUCTION, SHORING, UNSTABLE SOIL, CAVE-IN, BACKHOE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $50,000 to $250,000 2 24

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310599220 Hospitalized injury Other Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing plumbing, lighting fixtures
Fatality Cause: Trench collapse

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close