Accident Summary Nr: 202358917 - Employee Suffers Burns Torch Cutting Tops of Drums

Accident Summary Nr: 202358917 -- Report ID: 0352450 -- Event Date: 07/26/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30989346907/27/20063444332439Danzer Industries, Inc.

Abstract: At approximately 2:45 p.m. on July 26, 2006, a sheet metal worker was performing torch cutting, which involved cutting the lids off 55-gallon drums that had not been previously flushed or purged. The Plant Superintendent stated there were no written procedures for torch cutting and that no hot work-permit program existed. The employee stated he was directed by the Plant Superintendent to torch cut the lids from those drums that previously contained an extremely flammable paint solvent (Number R7K7210), manufactured by Sherman Williams. The employee began his work by leaning over the drum, and had just penetrated the lid when a flame shot out of the 2.5-in. bung hole. He sustained second- and third-degree burns to his chest, right shoulder and the right side of his face. He was initially treated by the Washington County Fire and Rescue Company, and was then taken to the Washington County Hospital Burn Unit.

Keywords: BURN, SHEET METAL, FLAMMABLE LIQUID, FLAMMABLE VAPORS, METAL SHOP, WORK RULES, FIRE, TORCH, FACE, CUTTING AND BURNING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309893469 Non Hospitalized injury Burn/Scald(Heat) Sheet metal workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close