Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202343919 - Employee Is Injured When Vapors Ignite and Explode

Accident Summary Nr: 202343919 -- Report ID: 0352420 -- Event Date: 05/09/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30611409105/09/20032851325510Lenmar Inc

Abstract: On May 9, 2003, Employee #1 was adding a micronized powder to a mixing tank containing xylene and toluene. The vapors ignited which resulted in an explosion and fire. Employee #1 sustained third-degree burns to his hands, arms, face and neck. He was hospitalized for treatment of his burns. The source of ignition appeared to have been static electric discharge produce by the addition of the powder.

Keywords: BURN, XYLENE, FIRE, TOLUENE, EXPLOSION, NECK, ARM, POWDER, FACE, HAND

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 306114091 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.