Accident Summary Nr: 202342465 - Worker Is Crushed and Killed While Correcting Cables

Accident Summary Nr: 202342465 -- Report ID: 0215000 -- Event Date: 01/13/2010
Inspection NrDate OpenedSICNAICSEstablishment Name
31408799001/13/20107699561790Ver-Tech Elevator Co. Inc.

Abstract: At approximately 5:50 p.m. on January 13, 2010, Employee #1, an elevator helper, with Ver-Tech Elevator Co. Inc, was riding atop the elevator car and servicing and inspecting the elevator. At the time, Employee #1 was inspecting for and correcting crossed and twisted hoist cables, when he was crushed between the top of the car (crosshead) and the top of the hoistway. Employee #1 was pronounced dead and was transported to the Office of Chief Medical Examiner (OCME).

Keywords: WIRE ROPE, CRUSHED, ELEVATOR, ELEVATOR SHAFT
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling Maintenance or repair Under $50,000 6 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 314087990 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.