Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202327763 - Employee asphyxiated while working in grain silo

Accident Summary Nr: 202327763 -- Report ID: 0420600 -- Event Date: 05/01/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30522448705/02/200220480Hillandale Farms Of Fla., Inc.

Abstract: On May 1, 2002, Employee #1, a feed mill laborer, was working inside a 42-foot high and 40-foot in diameter grain silo. The grain was being poured into silo while he was using a shovel to break up surface crust from the walls and dislodge caked corn from the 16-inch wide gravity- fed screw auger transfer unit, located beneath the floor of the silo. For some reason, Employee #1 became buried, chest high, in the flowing corn. He remained buried for four hours until rescue services freed him. Employee #1 died from asphyxiation.

Keywords: ASPHYXIATED, GRAIN, CORN, AUGER, BURIED, SILO

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 305224487 Fatality Asphyxia Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.