Accident Summary Nr: 202317970 - Employee Is Burned in Flash Fire

Accident Summary Nr: 202317970 -- Report ID: 0950653 -- Event Date: 09/26/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31167472509/26/20111442212321Matich Corporation

Abstract: At approximately 5:45 a.m. on September 26, 2011, Employee #1 was using a propane heating torch to free a stuck valve containing cold asphalt at an asphalt hot mix plant. A tank containing approximately 25 tons of hot PG64-10 asphalt oil was located approximately 4 to 6 in. from the valve. The tank's head space contained flammable vapors and its lid was not tightly sealed. When a flash fire occurred, Employee #1 was burned over approximately 14.5 percent of his body. He was hospitalized for treatment. An observer standing approximately 10 ft away sustained first-degree burns on his face, right hand and stomach. The employer had not performed a hazard assessment for the hot mix plant. Training consisted of what was shown to employees by senior employees. The injury line only included one employee.

Keywords: BURN, HEAT, FLAMMABLE VAPORS, FIRE, HOT ASPHALT, VALVE, ASPHALT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311674725 Hospitalized injury Burn/Scald(Heat) Miscellaneous plant and system operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close