Accident Summary Nr: 202317889 - Employee's Leg Is Fractured by Shattered Fan Pieces

Accident Summary Nr: 202317889 -- Report ID: 0950653 -- Event Date: 05/11/2009
Inspection NrDate OpenedSICNAICSEstablishment Name
31166865105/11/20091442212321Robertsons Ready Mix Inc

Abstract: On May 8, 2009, the crew at a sand and gravel plant discovered that a 400-HP, electric motor powering a cone crusher had lost its cooling fan cover. The plant was run dry, and the seemingly undamaged cover was replaced. On May 11, 2009, plant operations were started and ran for five hours, until the fan cover again fell off. The crew repaired some welding cracks in the motor support, replaced the cover after visually inspecting it, and restarted plant operations. Employee #1, a plant operator in training, went to the crusher deck to inspect motor function. As he walked past the motor, the fan disintegrated, and the aluminum cover shattered. A piece struck Employee #1, causing an open fracture of the tibia and fibula of his right leg, just above his ankle. Employee #1 was hospitalized. The investigation concluded that possible causes of the fan disintegration were damage to the fan caused by the cover falling off or preexisting fatigue cracks. Either condition would have been aggravated by excessive vibration from the cracked welds in the motor support.

Keywords: FRACTURE, DISINTEGRATED, TIBIA, STRUCK BY, FLYING OBJECT, LEG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311668651 Hospitalized injury Fracture Helpers, extractive occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close