Accident Summary Nr: 202315313 - Employee Is Struck by a Falling Object

Accident Summary Nr: 202315313 -- Report ID: 0950612 -- Event Date: 04/20/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
11964863205/10/20051771238110Joseph Albanese, Inc.

Abstract: On April 20, 2005, Employee #1 was stripping forms and removing tie wire from a radius curb. Employee #1 was wearing a hard hat and safety shoes. A Skytrak highlift truck operated by a coworker, was attempting to unload approximately 25 to 27 4-ft by 10-ft by 0.5-in. unbundled particle shear board panels. He was unloading them onto a second story residential house. Employee #1 was approximately 6 ft away from the unloading operation, when a gust of wind blew the top panel off the load and it struck him. Employee #1 received multiple fractures and was hospitalized.

Keywords: FRACTURE, HIGH WIND, IND TRK OPERATOR, CONSTRUCTION, INDUSTRIAL TRUCK, STRUCK BY, FLYING OBJECT, FALLING OBJECT
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling New project or new addition $1,000,000 to $5,000,000 3

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 119648632 Hospitalized injury Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pouring concrete foundations and walls
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.