Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202313359 - Employee Is Injured in Furnace Explosion

Accident Summary Nr: 202313359 -- Report ID: 0950612 -- Event Date: 08/23/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
11969063409/03/200233980Nitrex, Inc.

Abstract: On August 23, 2002, Employee #1, a manager of a night crew that hardens metal parts for train engines, was introducing disassociated ammonia into a furnace. An explosion occurred and he was struck by the concrete lid of the furnace, which blew off due to the force of the blast. Employee #1 was hospitalized and treated for multiple serious injuries. The cause of the explosion was not determined, but the cylinder was supposed to be completely purged of oxygen before ammonia was introduced.

Keywords: FURNACE, AMMONIA, EXPLOSION, CHEMICAL REACTION, STRUCK BY, FLYING OBJECT, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 119690634 Hospitalized injury Other Supervisors, production occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.