Abstract: This company does maintenance and rehabilitation of underground pipelines. One process used involves the placement of a "cured-in-place" lining on the inside of existing sewer lines. This involves inserting an inverted resin-impregnated felt tube from one manhole location to the next manhole. Through a process which circulates hot water through the inverted liner, a sufficient temperature is reached and maintained which hardens the resin to a fiberglass-like material. When the liner hardens, the excess hardened liner is removed and the hose is retracted. This process takes from 6 to 8 hours for 300 to 400 feet of liner. During one such liner installation, Employee #1 was caught by the powered roller which is used to insert and remove the lay-flat hose, and pulled around the roller, receiving injuries to his arm and legs. Employee #1 was hospitalized with a fracture.

Keywords: SEWER, FRACTURE, ROLLER--MACH/PART, CAUGHT BETWEEN, PIPELINE, MANHOLE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline Alteration or rehabilitation $50,000 to $250,000

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 304443088 Hospitalized injury Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing underground plumbing conduit
Fatality Cause: Other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.