Accident Summary Nr: 202289443 - Electric Shock - Contact with Overhead Line thru Boom

Accident Summary Nr: 202289443 -- Report ID: 0420600 -- Event Date: 09/22/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30282134309/27/199917940Christo, Inc.

Abstract: An employee was working in an excavation that was approximately 1 meter deep. He was positioning a catch basin being lowering by a backhoe. The boom on the backhoe contacted a 14-kilovolt overhead power line while the employee was holding the catch basin, and he was electrocuted.

Keywords: BACKHOE BOOM, OVERHEAD POWER LINE, ELECTRICAL, BOOM, ELECTROCUTED, CONSTRUCTION, E C, BACKHOE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling New project or new addition $1,000,000 to $5,000,000 2 20 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302821343 Fatality Electric Shock Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.