Accident Summary Nr: 202180170 - Employee Killed in Fall from Aerial Truck

Accident Summary Nr: 202180170 -- Report ID: 0253660 -- Event Date: 01/31/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31033079001/31/20071611237310Medina Vill Dpw Fatality 2007

Abstract: Between 10:30 a.m. and 10:45 a.m. on January 31, 2007, Employee #1 was removing hanging branches from a tree in a village-owned cemetery. He was working from the elevated platform of a 2004 Terex/Telelect XT60 High Ranger aerial platform truck. He was not wearing fall protection. The platform struck a tree limb and became inverted, causing Employee #1, along with the dielectric fiberglass platform liner, to fall from the platform. He fell approximately 25 feet and came to rest between the lower branches of the 3-foot diameter tree, approximately 8 feet to 9 feet above the ground. Three coworkers, who were positioned on the ground to cut and chip limbs felled by Employee #1, responded to him and called 911. Employee #1 was asphyxiated and was pronounced dead at the scene by the county coroner.

Keywords: ASPHYXIATED, CONSTRUCTION, TREE, FALL, FALL PROTECTION, ELEVATED WORK PLAT, TREE TRIMMING, AERIAL LIFT
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Highway, road, street Other Under $50,000 35 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 310330790 Fatality Asphyxia Miscellaneous material moving equipment operators Distance of Fall: feet
Worker Height Above Ground/Floor: 35 feet
Cause: Landscaping
Fatality Cause: Fall from/with bucket (aerial lift/basket)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.