Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202158531 - Employee killed when barge crane overturns

Accident Summary Nr: 202158531 -- Report ID: 0522900 -- Event Date: 05/07/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30160222305/08/20031629237990Underwater Construction Corporation

Abstract: Employee #1, the captain of the barge and the crane operator, was setting a 200-pound piling for the Ludington Power Plant fish net. He picked up the piling and the vibrator with the crane and was moving the load over the bow of the barge when the spotter noticed the line on the vibrator was tangled. Employee #1 swung the load to the left to untangle the line. Before Employee #1 could re-center the load, the crane toppled over pinning him in the cab of the crane. He suffered head injuries and was killed.

Keywords: BARGE, HEAD, PINNED, CRUSHED, CRANE, OVERTURN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Powerplant Maintenance or repair Under $50,000 10 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 301602223 Fatality Other Crane and tower operators Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pile driving
Fatality Cause: Caught in stationary equipment

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close