Accident Summary Nr: 202089413 - Worker Survives Sixty-Foot Fall from Grain Elevator

Accident Summary Nr: 202089413 -- Report ID: 0524700 -- Event Date: 08/17/2010
Inspection NrDate OpenedSICNAICSEstablishment Name
31378464708/20/20101799238290Elevator Services & Storage, Inc.

Abstract: At approximately 6:36 p.m. on August 17, 2010, Employee #1 was erecting a grain leg at a grain storage facility. Employee #1 had been hoisted to the work area in a personnel platform suspended by a mobile hydraulic crane. Employee #1 exited the platform and was working on top of the previously installed sections of grain leg. He was not wearing a harness or secured to an anchorage point. He was using a ratchet lever hoist ("come-a-long") secured to the grain leg and an adjacent concrete silo in order to square up the leg. He was adjusting the come-a-long in a forward motion, when the anchor in the concrete silo failed, causing Employee #1 to fall forward. He fell approximately 60 feet to compacted stone. Other employees on the site saw Employee #1 fall, and emergency crews were called immediately. One of the workers on the site provided first aid. Employee #1 was airlifted to the nearest trauma center. He sustained injuries including, but not limited to, skull fracture, cervical fracture, ruptured diaphragm, ruptured spleen, ruptured pancreas, multiple internal organ contusions, pelvic fractures, bilateral leg fractures, and arm fractures.

Keywords: ANCHOR, FRACTURE, HOISTING MECHANISM, CONSTRUCTION, EQUIPMENT FAILURE, FALL, FALL PROTECTION, NECK, GRAIN ELEVATOR, LEG
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition $50,000 to $250,000 6 60

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 313784647 Hospitalized injury Other Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 60 feet
Cause: Erecting structural steel
Fatality Cause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.