Accident Report Detail
Accident Summary Nr: 202087730 - One employee killed, two injured by truck on highway
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 309443711 | 10/13/2006 | 1611 | 237310 | Traffic Specialists, Inc. |
Abstract: At approximately 8:55 a.m. on October 12, 2006, Employees #1 through #3 and a coworker were replacing reflectors between two northbound lanes of a highway. The crew was using a mobile operation work zone system, in which there were two shadow vehicles behind the truck actually performing the maintenance work. Shadow vehicle #1 was approximately one-quarter to one-half of a mile ahead of shadow vehicle #2, a pickup truck with a flashing arrow board advising oncoming traffic of the work zone in the right lane. Shadow vehicle #2 was not on the roadway. Shadow vehicle #1 was parked on the road in the right lane, 80 to 100 ft behind the work vehicle; it was equipped with a truck-mounted Safe-Stop 180 TMA attenuator, as well as a flashing arrow board and a RIGHT LANE CLOSED sign. Employee #1, the crew foreman, had gotten out of shadow vehicle #1 to help Employees #2 and #3, who were with the work vehicle, prepare a series of reflectors for installation. All three employees were standing at the tailgate of the work vehicle when a tractor trailer traveling north on the highway failed to merge into the left travel lane. It was moving at approximately 55 mph when it struck shadow vehicle #1, pushing into the rear of the work vehicle and its tow-behind air compressor. The compressor struck Employees #2 and #3, throwing them off to the right. Both sustained injuries that required hospitalization. Shadow vehicle #1 landed on the left side of the work vehicle, crushing and killing Employee #1. At the time of the accident, there was no precipitation, the road was not reported to be wet, and no obstructions to visibility were reported.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Highway, road, street | Maintenance or repair | $50,000 to $250,000 | X | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 309443711 | Fatality | Other | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Traffic protection Fatality Cause: Crushed/run-over by highway vehicle |
||
| 2 | 309443711 | Hospitalized injury | Other | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Traffic protection Fatality Cause: Crushed/run-over by highway vehicle |
||
| 3 | 309443711 | Non Hospitalized injury | Other | Construction laborers | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Traffic protection Fatality Cause: Crushed/run-over by highway vehicle |
Translate