Accident Summary Nr: 202087524 - Employee's Finger Is Amputated While Operating Press

Accident Summary Nr: 202087524 -- Report ID: 0524700 -- Event Date: 03/27/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30944221804/28/20063469332116Sanc, Inc. Dba Figley Stamping Co.

Abstract: On March 27, 2006, Employee #1 was operating a bulldozer-type press that shaped capacitor clamps. The process required that the employee reach into the point of operation and place a flat metal blank into the die. The employee then depressed a foot pedal to actuate the press, and the press cycled. After the finished part would be removed from the die, a new blank was placed in, and the cycle was repeated. Employee #1 stated that she was reaching in to remove a completed part when the press cycled, partially amputating her left third and fourth fingers. The investigation revealed that the machine was not equipped with any type of guarding which would prevent the employee from reaching into the machine. The company also did not have a written safety and health plan, nor did they provide proper training.

Keywords: AMPUTATED, FINGER, FOOT CONTROL, MACHINE OPERATOR, POINT OF OPERATION, UNTRAINED, PRESS, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309442218 Hospitalized injury Amputation Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close