Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202085536 - Employee Suffers Amputation Using A Brake Press

Accident Summary Nr: 202085536 -- Report ID: 0524700 -- Event Date: 12/03/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30153328701/20/199930890Multilink Inc., Multifab Division

Abstract: Employee #1 was operating an 80-ton brake press bending small parts which required her fingers to be very close to the point of operation. The press was completely unguarded. Employee #1 suffered the amputation of three fingers. The operator working the previous shift had reported to his supervisor that the way the machine was set up required that his fingers be placed to close to the press. That employee was told there was nothing they could do and that he should be careful.

Keywords: AMPUTATED, PRESS BRAKE, FINGER, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301533287 Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.