Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202085304 - Employee killed when crushed by steel plate

Accident Summary Nr: 202085304 -- Report ID: 0524700 -- Event Date: 07/01/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
12197120407/01/199717940Dex Inc.

Abstract: Employee #1, a laborer, and a machine operator, who was also the owner and president of Dex, Inc., were working at a trench excavation. They were setting an 8 ft by 8 ft by 3/4 in. steel plate at the open end of a trench box in the excavation. The plate was being set at the west end of the stacked trench boxes already there. The regular practice was for the operator to set the plate into the trench using a three-leg wire rope sling attached to a hook on the bucket of the excavator while the laborer guided the lower portion of the plate close to the trench box. As the plate was set on the ground, it normally sunk into the earth and this provided support for the plate as it was unhooked from the sling. Once the plate was disconnected, the laborer would walk clear of it and the operator would position the boom/stick up and the bucket teeth down to push the plate into the ground. This same practice was followed on the day of the accident. After Employee #1 released the steel plate from the wire rope sling, he started to move clear of the plate so the operator could position the bucket of the Cat 245 excavator with its teeth down. The operator raised the boom/stick just as the plate began to teeter and fall backward toward Employee #1. He had enough time to turn around and see the plate as it fell, but he was unable to get clear. Employee #1 was crushed by the steel plate; he was pronounced dead at the scene.

Keywords: STEEL PLATE, TRENCH BOX, UNSECURED, CONSTRUCTION, TRENCH, CRUSHED, STRUCK BY, SET UP, OVERTURN, UNSTABLE POSITION
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Pipeline New project or new addition $500,000 to $1,000,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 121971204 Fatality Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Trenching, installing pipe
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.