Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202044244 - Employee killed when forklift rolls over

Accident Summary Nr: 202044244 -- Report ID: 0155010 -- Event Date: 11/22/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30236781811/22/199925150Burlington Department Ofpublic Works Distribution

Abstract: On November 22, 1999, Employee #1 was operating a Yale 3000 lb propane powered forklift on a driveway. While operating the forklift, the employee veered to the right and drove over a small drop-off to a lower driveway to a loading dock. The forklift rolled over and the overhead guard pinned the driver, killing him. The forklift was not equipped with seatbelts and the overhead guard was not a rollover protective structure.

Keywords: CHEST, IND TRK OPERATOR, PINNED, ROLL-OVER, ROPS, INDUSTRIAL TRUCK, TEXTILE PRODUCTION, STRUCK BY, UNTRAINED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 302367818 Fatality Other Industrial truck and tractor equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.