Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202014429 - Employee killed when caught in rotating agitator

Accident Summary Nr: 202014429 -- Report ID: 0216000 -- Event Date: 11/27/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30959665811/28/20061771238110Bronx Concrete Pumping Services, Corp.

Abstract: On November 27, 2006, Employee #1 was trying to release a jam in a concrete pumping truck when he became caught in the rotating agitator. Employee #1 was crushed and killed.

Keywords: ROTATING PARTS, CONCRETE TRUCK, CAUGHT BY, CONSTRUCTION, JAMMED, CRUSHED
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Multi-family dwelling Alteration or rehabilitation Under $50,000 1 8 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 309596658 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Pouring concrete floor at grade
Fatality Cause: Crushed/run-over by construction equipment during

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.