Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 202013355 - Employee Dies From Asphyxiation While Sandblasting Steel

Accident Summary Nr: 202013355 -- Report ID: 0216000 -- Event Date: 01/25/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
30280933002/07/200134330Yula Corporation

Abstract: Employee #1 died from asphyxiation while sandblasting stainless steel. He was wearing a supplied air respirator. Employee #1 was required by his employer to wear the respirator when he was sandblasting stainless steel heating coils. A compressed air cylinder was used to supply the air. Employee #1 was transported to a nearby hospital where he died in the emergency room.

Keywords: AIR LINE RESPIRATOR, ASPHYXIATED, STEEL, COMPRESSED AIR, SANDBLASTING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 302809330 Fatality Asphyxia Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.