Accident Summary Nr: 202013041 - FALL FROM ELEVATION

Accident Summary Nr: 202013041 -- Report ID: 0216000 -- Event Date: 01/17/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
11060695101/21/199773630Comforce Telecom Inc

Abstract: An employee was installing two nuts onto two bolts on the bottom of an antenna mounted on the roof of a building. The employee was wearing a harness (Petzl Model No. 962548 2) with a rope grab. A 16-millimeter-diameter life line had been installed; however, the rope grab was not attached to the lifeline. The employee was either leaning over the 760-millimeter-high parapet or sitting astraddle it. He fell 16.5 meters to the ground. The employee died of his injuries.

Keywords: ROOF, LIFELINE, TELECOM WORK, FALL, FALL PROTECTION, ANTENNA, UNTRAINED, COMMUNICATION WORKER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110606951 Fatality Other Electronic repairers, communica. & indus. equip.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.