Accident Summary Nr: 202005518 - Employee Is Fatally Struck by a Crane's Falling Load Block

Accident Summary Nr: 202005518 -- Report ID: 0317000 -- Event Date: 06/23/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31423533406/23/20111731238210Matrix Service Industrial Contractors, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
31423543306/23/20114961221330Veolia Energy Philadelphia, Inc.
Inspection NrDate OpenedSICNAICSEstablishment Name
31423560706/24/20113536333923Permadur Industries, Inc. T/A Sissco

Abstract: On June 23, 2011, Employee #1 working for an electrical subcontractor was assisting Employee #2, the crane operator in the movement of a gang box (owned by the electrical subcontractor) via a permanently installed overhead bridge crane. The crane had two hoists (80 ton Main Hoist (MH) & 10 ton Auxiliary Hoist (AH)). The crane was remote controlled. The crane's MH was being used to lower the gang box to a different level. Employee #1 was assisting Employee #2 in the rigging of the gang box and connecting it to the MH load block's hook. Employee #2 briefly operated the AH controller thinking he was actuating the MH controller on the remote control box. Employee #2 then moved his hand over to the MH controller and raised the gang box several feet so it could pass over an adjacent guardrail. Prior to the crane moving the gang box horizontally, a loud noise was heard from above. Subsequently the AH load block assembly became separated from its wire rope load line and came crashing down striking Employee #1 who was standing directly under it. This AH load block weighed 231 pounds and free fell approximately 35 feet. The AH upper limit switch assembly did not function to prevent the two-block condition. Two-blocking occurs when the hoist block comes into contact with a structural component of the crane's trolley assembly and ultimately causing the hoist's wire rope to break. The AH upper limit switch was not tested for proper operation prior to use. The crane was not used daily. Employee #2 was an employee of the company who owned the crane. Employee #1 died from his injuries.

Keywords: OVERHEAD CRANE, CRANE OPERATOR, RIGGING, GUARDRAIL, ROPE, HOIST, STRUCK BY, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Powerplant Alteration or rehabilitation $250,000 to $500,000 3 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 314235334 Fatality Fracture Electricians Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Installing equipment (HVAC and other)
Fatality Cause: Struck by falling object/projectile
2 314235433 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:
3 314235607 Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause:

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.