Accident Summary Nr: 202004933 - Employee Is Killed While Working on Skid Steer Loader

Accident Summary Nr: 202004933 -- Report ID: 0317000 -- Event Date: 01/25/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31071432401/25/20070782561730P.H. Mccullough, Inc.

Abstract: On January 25, 2007, Employee #1 was working for a landscaping service, performing maintenance on a skid steer loader. With the operator's cab tilted forward, he inadvertently actuated the loader lift arms while he was in the seating area. This action pushed the cage back toward the operating position, pinning his chest between the seat and the underside of the cage. He was crushed and killed.

Keywords: MAINTENANCE, ASPHYXIATED, CAUGHT BETWEEN, CRUSHED, SKIDDER

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310714324 Fatality Other Supervisors, material moving equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.