30263069406/09/200017960Frank W. Hake, Inc.

Abstract: On June 9, 2000, Employee #1, a journeyman iron worker, a coworker, and the job foreman were replacing metal roof deck sheets on a low-pitched roof. The deck sheets had been removed five days earlier to allow access to a bridge crane so that repairs could be made to the drum. For some reason, Employee #1 stepped onto the end of a deck sheet that was unsupported and had not yet been secured. Both he and the metal sheet fell 130 ft through the roof opening to the ground. Employee #1 was killed. Employee #1 and the two coworkers were apparently wearing full body harnesses and 6 ft shock-absorbing lanyards at the time of the accident, but none of the workers had their lanyards connected to an anchor point.

Keywords: INSTALLING, ROOF, DECKING PANEL, UNSECURED, UNSECURED PANEL, WORK RULES, CONSTRUCTION, FALL, ROOF OPENING, TIE-OFF
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Manufacturing plant Maintenance or repair $250,000 to $500,000 1 150 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 302630694 Fatality Other Roofers Distance of Fall: feet
Worker Height Above Ground/Floor: 130 feet
Cause: Roofing
Fatality Cause: Fall from roof

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.