Accident Summary Nr: 201991601 - Employee Suffers Fractured Leg When Crane Tipped Over

Accident Summary Nr: 201991601 -- Report ID: 0950411 -- Event Date: 03/25/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30875627903/25/20051751238130Graber Construction Company

Abstract: A crane operator was operating a 23.5-ton truck crane with a telescoping boom. The operator arrived at a residential construction site (a two-story frame home), parked his truck crane in the street and set the crane outriggers. The operator extended the boom to the full length which was 92 ft at a boom angle of approximately 53 degrees which corresponds to a lifting radius of 50 ft. The lifting capacity or load rating at this boom angle and boom height is 3,025 pounds. The distance from the point where the plywood was to be landed to the centerline of the crane turret was approximately 58 ft to 60 requiring a boom angle of 49 degrees with a load rating of 2,425pounds. The operator cabled-down to lift a bundle consisting of 87 sheets of 4-ft-by-8-ft-by-0.5-in. x 1/2" plywood. Each sheet of plywood weighed approximately 49 pounds each. The total load of the bundle at the site according to the shipping invoice was 4,303 pounds. Two synthetic web slings were attached to the load in a choker method and attached to the crane hook by the framing foreman. The operator cabled-up to clear the second floor of the structure and as the crane rotated clockwise toward the driver's side of the truck it started to tip over. As the crane tipped over the boom structure came down through the second story of the structure coming to rest on a supporting beam on the first floor. Employee #1, from the framing company, was standing on the second floor in order to guide the load in place, and had to jump from the back of the structure to avoid being struck by the boom. Employee #1 stated that the crane boom just glanced off his right shoulder pushing him off the structure. Employee #1 fractured his leg severely when he fell into the back yard. The crane operator was shaken but uninjured. According to the crane operator the crane is equipped with an override safety system that monitors the boom angle, length, lifting radius and load with an audible alert that beeps if the crane is overloaded. The operator stated that the audible alarm went off as the crane was tipping which did not give the operator time to cable down or raise the boom. Employee #1 was hospitalized.

Keywords: FRACTURE, SHOULDER, CRANE BOOM, ALARM, CONSTRUCTION, FALL, STRUCK BY, FALLING OBJECT, CRANE, LEG
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $250,000 to $500,000 2

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 308756279 Hospitalized injury Fracture Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: 16 feet
Cause: Exterior carpentry
Fatality Cause: Fall, other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.