Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201954500 - One Employee Is Injured, One Later Dies from Toxic Release

Accident Summary Nr: 201954500 -- Report ID: 0522000 -- Event Date: 02/15/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30970253802/15/20062869325199Rohm And Haas Chemicals, Llc

Abstract: At approximately 9:00 a.m. on February 15, 2006, Employee #1 and Employee #2 were unclogging a plugged steam ejector and became unconscious. Apparently, an organo-sulphur compound decomposed, liberating hydrogen sulfide and carbon monoxide when it became exposed to temperatures in the vicinity of 160-degrees Celsius. No local monitoring for hydrogen sulfide, carbon monoxide, oxygen or LEL was performed prior to the start of the maintenance. Employee #1 passed out shortly after the line was broken by the removal of a flange. Employee #2 contacted the Emergency Response Team indicating that it appeared Employee #1 was experiencing a heart attack. Employee #2 began to lift up and move Employee #1, but he, too passed out. Emergency Response Team members arrived. CPR was performed. Both were rushed to the hospital. Employee #2 gradually recovered and was released from the hospital on February 19, 2006. Employee #1 never came out of his coma and died on February 18, 2006.

Keywords: HEAT, MAINTENANCE, UNCONSCIOUSNESS, ASPHYXIATED, HEART ATTACK, HYDROGEN SULFIDE, TOXIC ATMOSPHERE, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309702538 Fatality Asphyxia Painters, construction and maintenance
2 309702538 Hospitalized injury Asphyxia Painters, construction and maintenance

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close