Accident Summary Nr: 201953429 - Employee killed in explosion of charge tank

Accident Summary Nr: 201953429 -- Report ID: 0522000 -- Event Date: 04/02/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30644703804/02/20032821325211Bayer Polymers Llc

Abstract: . On April 2, 2003, Employee #1 and a coworker, the technicians, were watching a polymerization process involving styrene and acrylonitrile monomers. Employee #1 and the coworker's jobs involved monitoring a reactor vessel throughout the process. At the end of the batch process, non-polymerized monomer and vapors were stripped from the reactor through a condenser system to a distillate collection tank and were ultimately charged to subsequent batches. Toward the end of the stripping process, Employee #1 left the control room to determine if enough distillate had been removed to allow the remaining water and mixture to be dumped to the "dirty" sewer and a collection system. While Employee #1 was in the vicinity of the reactor, an explosion occurred in a small auxiliary charge tank. A piece of metal struck Employee #1's abdomen and killed him. Although the charge tank was not in use at the time of the accident, a small amount of the batch had back-flowed through a valve between the reactor and the auxiliary tank during the reactive process. The batch continued to react in the auxiliary tank, overheating and overpressurizing the tank.

Keywords: ABDOMEN, REACTOR, ACRYLIC MONOMER, EXPLOSION, STYRENE, STRUCK BY, OVERHEATED, TANK, CHARGE BUCKET

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 306447038 Fatality Other Technicians, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close