Accident Summary Nr: 201952603 - Employee amputates fingertip when caught by clamp

Accident Summary Nr: 201952603 -- Report ID: 0522000 -- Event Date: 07/31/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
1805154008/17/20003465336370Select Tool & Die Corp.

Abstract: On July 31, 2000, Employee #1, a fixture technician, was performing minor maintenance on a TRW Robotic Can Assembly. The employee reached up to tap a can back into place on Fixture #1 and got her right index finger caught between a closing clamp and the can. At this point, the machine unexpectedly activated and amputated the tip of her right index finger. The machine was not locked out or turned off before beginning the work.

Keywords: MAINTENANCE, AMPUTATED, ROBOT, FINGER, METAL SHOP, WORK RULES, LOCKOUT, CAUGHT BETWEEN, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 18051540 Non Hospitalized injury Amputation Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.