Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201951894 - Employee Killed In Fall From The Top Of A Grain Bin

Accident Summary Nr: 201951894 -- Report ID: 0522000 -- Event Date: 01/17/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
10322610601/18/200051530Champaign Landmark, Inc.

Abstract: On January 17, 2000, Employee #1 was checking the level of soy beans in a grain bin because of an inconsistency with the inventory and the fact that beans had been transferred from this bin to other bins for off-loading. The eave of the bin is 73 ft above ground level and the sloped roof angled up approximately another 20 ft. The bin top has a flat area estimated to be about 8 ft in diameter, but is largely restricted by a super flow conveyor, conduit, and other equipment. On the flat area is a circular hatch opening (approximately 6 in. in diameter) with a lid where employees take one grain measurement. A second measurement is taken at the eave level through a man hole at the side of the bin opposite the 6-in. hatch opening. Access to the man hole is down a series of steps built into the slope of the bin which run from the bin top to the eave. A catwalk with standard guardrails is used to gain access to the top of the bin. However, the railing did not extend the full length of the catwalk nor was the end of the catwalk guarded. The last upright of the guardrail also served as one of the side rails for a fixed, 4-rung ladder employees use to gain access to the top of the bin. The other side rail was formed by a single, vertical piece of angle iron. On the bin top the available walking space was estimated by employees to be approximately 2.5 ft due to the obstructions. It would be necessary to take several steps to either side of the ladder to remove the cover from the 6-in. hatch or to access the steps which led to the man hole. There were no guardrails or equivalent protection on the top of the bin, and the steps had a railing on only one side that did not have a mid-rail or toe board. Employee #1 fell from the top of the grain bin and was killed.

Keywords: GUARDRAIL, FALL, GRAIN ELEVATOR, MIDRAIL, GRAIN BIN, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 103226106 Fatality Other Supervisors; handlers,equip-cleaners,laborers nec

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close