Accident Summary Nr: 201951431 - Employee amputates fingers when caught in mixer

Accident Summary Nr: 201951431 -- Report ID: 0522000 -- Event Date: 02/04/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
12198070004/07/199934430The Jos. Honhorst Co.

Abstract: On February 4, 1999, Employee #1 was working as a steel fabrication and welding contractor. The employee was cutting a 2-in. diameter hole in the discharge (drainage) cone at the bottom of a vacuum dryer which measured 8 feet in diameter and 30 feet long. The employee then planned to weld a drain pipe to the hole he cut. The diameter of the cone opening at the base of the dryer was 1.5 feet in diameter. Although the employee had worked on various aspects of vacuum dryers in the past at this employer's site, the installation of a drain at this location was new. Because the cone and the inside of the tank were made of stainless steel and the employee was using a plasma arc to cut the hole, the employee pushed a welding blanket into the cone opening to protect the inside of the tank from receiving flash or slag from the cutting. When Employee #1 inserted the welding blanket, one of the mixer plows (paddles or blades) caught the blanket along with the employee's hand. The employee was hospitalized when his index finger was amputated at the third knuckle, along with approximately half of the thumb, and the tip of the middle finger. The employee did not know that, in preparation for start up, the host employer had turned on the mixer plows in the dryer several days earlier to ensure the plows did not scrape the lining of the tank before adding product. Performing a test of the dryer in this manner was normal procedure since there is only about 0.0625-in. clearance between the bottom of the plows and the inside of the tank.

Keywords: AMPUTATED, DRAIN PIPE, FINGER, WORK RULES, WELDER, LOCKOUT, TEST EQUIPMENT, UNGUARDED LIVE PARTS, UNTRAINED, ARC WELDING

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 121980700 Hospitalized injury Amputation Boilermakers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close