Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 201931185 - One Employee Killed One Injured in Boom Collapse

Accident Summary Nr: 201931185 -- Report ID: 0419000 -- Event Date: 08/17/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
30141550108/21/20074491488320M. Bowling Marine, Inc.

Abstract: A coworker of Employee #1 went under a boom after removing the bolts while trying to remove a section of the boom. Employee #1, the foreman, jumped from the front-end loader that he was operating to get the coworker out from under the boom. The boom fell on Employee #1 killing him instantly and injuring the coworker. The Injury Line in the original report does not list the injured coworker and the narrative gives no details of the injuries sustained by the coworker.

Keywords: HEAD, FRONT END LOADER, COLLAPSE, CRANE BOOM, STRUCK BY, CONCUSSION, FALLING OBJECT, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 301415501 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close